Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12494/35965
Exportar a:
Title: Evaluación de la distribución de esfuerzos de una restauración inmediata implantosoportada en tres fases de cicatrización. Análisis de elementos finitos
Author: Rodríguez López, Mauricio Alejandro
Giraldo Gómez, Samuel David
Latorre Correa, Federico
Villarraga Ossa, Junes Abdul
Diosa Peña, Juan Gustavo
Email autor: samuel.giraldo@campusucc.edu.co
Issue Date: Apr-2019
Keywords: Pilar Peek
Pilar titanio
Implante dental
Análisis de elementos finitos
Distribución de esfuerzos
Resume: Introducción: evaluar la distribución de esfuerzos von Mises en restauraciones implanto soportadas, con un pilar temporal de Peek y uno de titanio, en tres etapas de cicatrización (día cero, 1.5 meses y 3 meses). Estas evaluaciones fueron realizadas por medio del método de análisis de elementos finitos (mef). Métodos: se modeló un implante Tapered Screw-Vent® (ref. TSVB10 Zimmer Dental) de 13 mm de longitud por mm diámetro con una plataforma de 3.5 mm, un pilar de Peek, un pilar de titanio, un tornillo, una corona de Pmma de un incisivo central superior, un hueso cortical y esponjoso con diferentes densidades dependiendo del estadio de cicatrización; se utilizó el Software cad de Solid Works 2010, se procesó y analizó a través del Software ansys versión 14. Se evaluó la distribución de esfuerzos von Mises, aplicando cargas en sentido oblicuo con una magnitud de 200N. Resultados: la concentración de stress en el hueso esponjoso apical es 10 veces mayor en el día cero que en los demás momentos de cicatrización. Los modelos de pilares en Peek en el momento 1.5 y 3 meses mostraron casi dos veces mayores esfuerzos en el implante que los modelos en titanio; se observaron valores similares von Mises al comparar el momento 1.5 y 3 meses. Conclusiones: en el día cero de cicatrización se concentra la mayor cantidad de esfuerzo en la porción apical del hueso esponjoso, los pilares de Peek trasmiten mayor esfuerzo al tornillo del implante, la formación de hueso crestal ayuda a una mejor distribución de los esfuerzos en el sistema.
Abstract: Introduction: to evaluate the distribution of von Mises stress in implant-supported restorations, with a temporary pillar of Peek and one of titanium, in three stages of healing (zero day, 1.5 months and 3 months). These evaluations were carried out by means of the finite element analysis (fem) method. Methods: A Tapered Screw-Vent® implant (ref.: TSVB10 Zimmer Dental) of 13 mm length by 3.7 mm diameter was modeled with a 3.5 mm platform, a Peek abutment, a titanium abutment, a screw, a crown Pmma of an upper central incisor, a cortical and spongy bone with different densities depending on the stage of healing; the Solid Works 2010 cad Software was used, processed and analyzed through the ansys Software version 14. The von Mises stress distribution was evaluated, applying oblique loads with a magnitude of 200N. Results: the concentration of stress in the apical spongy bone is 10 times greater on day zero than in the other moments of healing. The models of abutments in peek at the time 1.5 and 3 months showed almost two times greater efforts in the implant than the models in titanium; similar values were observed von Mises when comparing the moment 1.5 and 3 months. Conclusions: on the zero day of healing the greatest amount of effort is concentrated in the apical portion of the cancellous bone, the Peek pillars transmit more effort to the implant screw, the crestal bone formation helps a better distribution of the stress in the system.
Table Of Contents: 1. Resumen. -- 2. Introducción. -- 3. Materiales y métodos. -- 4. Resultados. -- 5. Discusión. -- 6. Conclusiones. -- 7. Conflicto de interes.
Program: Ciencia Inclusiva
Headquarters: Externo
Type: Artículos Científicos
Citation: Rodríguez López, M. A., Giraldo Gómez, S. D., Latorre Correa, F., Villarraga Ossa, J. A., & Diosa Peña, J. G. (2019). Evaluación de la distribución de esfuerzos de una restauración inmediata implantosoportada en tres fases de cicatrización.: Análisis de elementos finitos. Revista Nacional De Odontología, 15(28). https://doi.org/10.16925/2357-4607.2019.01.06
Appears in Collections:Artículos Científicos Accesibles

Files in This Item:
File Description SizeFormat 
6_Evaluacion distribucion.docx541.2 kBMicrosoft Word XMLView/Open Request a copy
6_Evaluacion_distribucion.epub1.74 MBUnknownView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.