Please use this identifier to cite or link to this item: http://hdl.handle.net/20.500.12494/11409
Exportar a:
Title: Apoyo de ingeniería civil en la asociación de usuarios del distrito de adecuación de Tierras de mediana escala el juncal “ASOJUNCAL” Municipio De Palermo – Departamento Del Huila
Author: Lozano Díaz, Fabio Ernesto
Oviedo Vargas, Mayra Natalia
Tovar Barrera, Leidy Yurani
Email autor: leidy.tovarb@campusucc.edu.co
Fabioe.lozano@campusucc.edu.co
mayra.oviedov@campusucc.edu.co
Issue Date: 11-Jun-2019
Advisor / Validator: Perez Pedreros, Humberto
Keywords: Distrito de riego
Fallas y fisuras en estructuras de concreto
Concreto reforzado
Georreferenciación
Resume: El estudiante de ingeniería civil debe adaptar conceptos teóricos adquiridos durante el pregrado a casos prácticos; para desarrollar criterio de diagnóstico en el momento de estudio del comportamiento de una estructura, evidenciando las fallas y planteando medidas correctivas para recuperar las condiciones de funcionamiento de la estructura. El canal revestido en concreto simple del Distrito de Adecuación de Tierras de Mediana Escala El Juncal “ASOJUNCAL” presenta afectación en su vida útil, debido a que ha soportado factores de humedad, temperatura y presión por más de 50 años; evidenciándose fallas de tipo estructural que generan pérdida de carga por filtración, disminuyendo su eficiencia. Para subsanar esta problemática, se inspeccionó visualmente la red de canales de la zona C del distrito de adecuación de tierras de mediana escala el Juncal; verificando sus medidas y reportando la ubicación de las áreas afectadas, los tipos y dimensión de fallas que presentan estableciendo su grado de severidad. Se emitió planos con coordenadas reales y memoria de cálculo del presupuesto de costo de mantenimiento y revestimiento en concreto reforzado, lo que fue necesario de estudiar el Título C de las Especificaciones Técnicas del Reglamento Colombiano de Construcción Sismo Resistente NSR-10 y los Requisitos de Reglamento para Concreto Estructural (ACI 318S-05).
Abstract: The student of civil engineering must adapt the theoretical concepts that were acquired during undergraduate to practical cases. Developing the diagnostic criteria at the time of the study of the behavior of a structure; proving the failures and proposing corrective measures to recover the operating conditions of the structure. The channel is classified into simple concrete, the District of Land Adaptation of Medium Scale The Juncal "ASOJUNCAL". It shows the affectation in its useful life, due to it has supported the factors of humidity, temperature and pressure for more than 50 years. Evidencing faults of structural type that generate loss of load by filtration, diminishing its efficiency. To solve this problem, the network of channels of zone C of the district of adaptation of land of medium scale El Juncal was visually inspected; verifying its measurements and reporting the location of the improved areas, the types and the dimension of failures that they present, establishing their degree of severity. Plans were issued with the real indications and the calculation of the cost of the cost of maintenance and the lining in reinforced concrete, which was necessary to study the Title C of the Technical Specifications of the Colombian Regulation of Earthquake Resistant Construction NSR-10 and the Requirements of the Regulation for structural concrete.
Table Of Contents: Introducción. -- 1. Descripción y naturaleza de la organización. -- 1.1 Misión. -- 1.2 Visión. -- 1.3 Valores. -- 2. Planteamiento del problema. -- 2.1 Descripción del problema . -- 3. Objetivos. -- 3.1 Objetivo general . -- 3.2 Objetivos específicos. -- 4. Plan de acción. -- 5. Acciones de mejora a implementar durante la práctica. -- 6. Actividades realizadas. -- 6.1 Información preliminar. -- 6.1.1 Técnica de recolección de datos. -- 6.1.2 Instrumentos de recolección de datos. -- 6.2 Diagnóstico. -- 6.2.1 Definición de convenciones y variables de daños en el canal. -- 6.3 Análisis y cuantificación. -- 6.4 Presupuesto. -- 6.4.1. Temporales de obra. -- 6.4.2 Localización y replanteo. -- 6.4.3 Demoliciones. -- 6.4.4 Disposición de sobrantes. -- 6.4.5 Desmonte y limpieza. -- 6.4.6 Excavación y nivelación. -- 6.4.7 Relleno y compactación. -- 6.4.8 Concreto. -- 6.4.9 Acero de refuerzo. -- 6.4.10 Formaleta. -- 7. Logros y lecciones aprendidas. -- 8. Conclusiones. -- Recomendaciones. -- Bibliografía. -- Anexos. --
Program: Ingeniería Civil
Headquarters: Neiva
Type: Trabajos de grado - Pregrado
Citation: Tovar, L; Oviedo, M; & Lozano; F. (2019). Apoyo de ingeniería civil en la asociación de usuarios del distrito de adecuación de Tierras de mediana escala el juncal “ASOJUNCAL” Municipio De Palermo – Departamento Del Huila. Neiva: Recuperado de: http://repository.ucc.edu.co/handle/ucc/11409
Appears in Collections:Ingeniería Civil

Files in This Item:
File Description SizeFormat 
2019-Tierras- ASOJUNCAL-Huila.pdfTrabajo de grado12.75 MBAdobe PDFView/Open
2019-Tierras- ASOJUNCAL-Huila-LicecniaUso.pdfLicencia de uso146.56 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.