Please use this identifier to cite or link to this item: http://repository.ucc.edu.co/handle/ucc/6462
Exportar a:
Title: Evaluación de la rugosidad superficial de dos sistemas adhesivos de uso en ortodoncia y su relación con la adhesión bacteriana. Estudio experimental in vitro.
Author: Buitrago Vargas, Jhony Alexis
Gómez Chitiva, María del Rosario
Email autor: jhony.buitrago@campusucc.edu.co
mariadr.gomez@campusucc.edu.co
Issue Date: 2018
Advisor / Validator: Delgado Perdomo, Linda Piedad
Ruíz Gómez, Adiela
Peláez Vargas, Alejandro
Keywords: Rugosidad
Resinas compuestas
Adhesión bacteriana
Resume: Introducción: los adhesivos de uso en ortodoncia proporcionan condiciones para la colonización de microorganismos en cavidad oral, por lo tanto, las características de la superficie de los biomateriales son determinantes en la adhesión bacteriana. Objetivo: evaluar la rugosidad superficial in vitro de dos sistemas adhesivos para cementación de brackets y su relación con la adhesión bacteriana de S. mutans. Materiales y Métodos: se realizó una investigación experimental in vitro con dos adhesivos de ortodoncia Enligth® y Transbond XT®, para medir la rugosidad superficial promedio Ra. Se usaron ensayos in vitro para evaluar la adhesión de S. mutans en los discos a las 4, 8 y 24 horas de incubación. La adhesión bacteriana se determinó usando el ensayo MTT y el método de unidades formadoras de colonias (UFC). Los discos de resinas se caracterizaron por microscopía electrónica de barrido (SEM). Se utilizó la prueba de U de Mann-Whitney para dos muestras independientes. Resultados: los resultados fueron estadísticamente no significativos (p = 0,082) para el parámetro Ra. En la adhesión in vitro mediante UFC, se observó mayor adhesión de S. mutans en la resina Transbond XT® (p = 0,009) a las 8 horas. En MTT, se observó mayor adhesión de S. mutans en la resina Transbond XT® (p = 0,015) a las 4 horas. Las imágenes SEM mostraron adhesión bacteriana en todas las superficies sin diferencias entre las dos resinas. Conclusiones: la adhesión bacteriana y la rugosidad superficial es diferente en los dos sistemas adhesivos. No se puede establecer una relación entre la rugosidad superficial de los dos sistemas adhesivos debido a que no se tuvieron en cuenta factores como energía libre superficial, interacción ácido base y fuerzas de Van der Wals. No existe diferencia significativa en la rugosidad superficial promedio (Ra) entre los dos sistemas de adhesión, sin embargo, en los parámetros Rt y Ry si se presentaron diferencias significativas, con valores mayores para la resina Transbond XT®.
Abstract: Introduction: the use of adhesives in the orthodontics of the conditions for the colonization of microorganisms in the oral cavity, therefore, the characteristics of the surface of the biomaterials are determining in the bacterial adhesion. Objective: to evaluate the superficial rugosity in vitro of the adhesive systems for the cementation of supports and the bacterial relation of S. mutans. Materials and Methods: An experimental in vitro research was carried out with two orthodontic adhesives Enligth® and Transbond XT®, to measure the average surface roughness Ra. In vitro tests were used to evaluate the adhesion of S mutans in the discotheques at 4, 8 and 24 hours of incubation. Bacterial adhesion was determined by the MTT assay and the colony forming unit (CFU) method. Resin discotheques are characterized by scanning electron microscopy (SEM). It is applied to the Mann-Whitney U test for two independent samples. Results: the results were statistically not significant (p = 0.082) for the Ra parameter. In the in vitro adhesion by CFU, a greater adhesion of S mutans was observed in the Transbond XT® resin (p = 0.009) at 8 hours. In MTT, greater adhesion of S. mutans was observed in the Transbond XT® resin (p = 0.015) at 4 hours. SEM images give bacterial adhesion on all surfaces without differences between the two resins. Conclusions: bacterial adhesion and surface roughness is different in the two adhesive systems. It is not possible to establish a relationship between the surface roughness of the systems of the adhesive systems. There is no significant difference in the average surface roughness (Ra) between the two adhesion systems, however, in the parameters Rt and Ry if there are significant differences, with higher values for the Transbond XT® resin.
Program: Especialización en Ortodoncia
Headquarters: Bogotá
Publisher: Universidad Cooperativa de Colombia, Posgrado, Especialización en Ortodoncia, Bogotá
Citation: Buitrago Vargas, J. A. y Gómez Chitiva, M. R. (2018). Evaluación de la rugosidad superficial de dos sistemas adhesivos de uso en ortodoncia y su relación con la adhesión bacteriana. Estudio experimental in vitro. ( Tesis de Especialización). Recuperado de: http://repository.ucc.edu.co/handle/ucc/6462
Appears in Collections:Ortodoncia

Files in This Item:
File Description SizeFormat 
2018_EvaluaciónRugosidad-Ortodoncia-AdhesionBacteriana.pdfTrabajo de grado401.67 kBAdobe PDFView/Open
2018_EvaluaciónRugosidad-Ortodoncia-AdhesionBacteriana_LicenciadeUso.pdfLicencia de uso499.82 kBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.